3-30
MAINTENANCE
powermax600 Service Manual
Work Cable Replacement
Disconnect electrical power and gas supply before removing the old work cable.
Installation - Refer to Figure 3-14.
Install the strain relief (1) to the power supply and secure with nut (2).
Install work cable (3) through the strain relief.
Tie a knot (4) in the end of the work cable.
Tighten the strain relief collar (5) onto the cable.
Connect the work cable to the terminal block (6).
Tighten terminal block screw to 10 in-lb (12 kg cm) of torque.
Install the power supply cover.
Figure 3-14 Work Cable Replacement
CAUTION: This is a high current connection.
Proper torque is critical.
PMX600.15