MAINTENANCE AND PARTS
10-99
5-8 powermax600 Operator Manual
Air Filter Element Replacement
Compress the hose fitting collar and
pull the gas hose from the hose fitting.
Pull the drain hose from the grommet
in the floor of the power supply.
Unscrew the filter bowl. Do not
discard the O-ring.
Remove the filter element from
the filter housing.
NOTE: Do not allow the filter element to turn
when loosening the screw.
Removal
Disconnect electrical power.
Disconnect gas supply.
Remove the power supply cover.
WARNING
ELECTRIC SHOCK CAN KILL
Disconnect electrical power before performing any maintenance.
All work requiring removal of the power supply cover must be
performed by a qualified technician.