Troubleshoot Common Problems
6
142 810470 Operator Manual Powermax65/85/105 SYNC
0-60-0
Yellow
Yellow
An AC input voltage phase
loss occurred.
This is applicable only to CE
models and to
Powermax105 SYNC CSA
models.
This fault code stops the system from operating.
Do the following. A cold restart is necessary.
Have an electrical technician examine all
input phases and fuses/breakers for correct
voltage at the power source and at the
plasma power supply.
If applicable, disconnect the system from
generator power, or set the generator mode
feature to on. Refer to Troubleshoot
power-related problems with generators on
page 145.
0-60-1
Yellow
Yellow
An AC input voltage is too
low.
This fault code stops the system from operating.
Do the following. A cold restart is necessary.
The input line voltage is too low (more than
15% below the rated voltage). Have an
electrical technician examine the line and
increase the voltage. Refer to page 24 and
page 41.
If applicable, disconnect the system from
generator power, or set the generator mode
feature to on. Refer to Troubleshoot
power-related problems with generators on
page 145.
0-60-2
Yellow
Yellow
An AC input voltage is too
high.
This fault code stops the system from operating.
Do the following. A cold restart is necessary.
The input line voltage is too high (more than
10% above the rated voltage). Have an
electrical technician examine the line and
decrease the voltage. Refer to page 24 and
page 41.
If applicable, disconnect the system from
generator power, or set the generator mode
feature to on. Refer to Troubleshoot
power-related problems with generators on
page 145.
Fault
code
Fault
icon
Fault
LEDs Description Solutions

Table of Contents

Other manuals for Hypertherm SYNC Powermax 85

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm SYNC Powermax 85 and is the answer not in the manual?

Hypertherm SYNC Powermax 85 Specifications

General IconGeneral
BrandHypertherm
ModelSYNC Powermax 85
CategoryWelding System
LanguageEnglish

Related product manuals