Page #141 background imageLoading...
Page #141 background image
Troubleshoot Common Problems
6
Powermax65/85/105 SYNC Operator Manual 810470 141
0-50-2 none
Yellow
The torch-lock switch is set to
the green “ready to fire” ( )
position, but the torch is not
prepared to fire.
This fault code identifies a condition in which an
additional step is necessary for hand torches
before the hand torch will fire a plasma arc.
When you move the torch-lock switch to the
green “ready to fire” ( ) position, the fault
code changes from 0-50-1 to 0-50-2, and
the icon goes off.
Hand torch: Fire the torch 1 time to get the
warning puffs of air. The 0-50-2 fault code
goes off, and the LED on the hand torch
changes from yellow to green. The torch is
now prepared to fire a plasma arc.
Machine torch: The 0-50-2 fault code
shows for approximately 1 second and then
goes off. Fire the torch to get a plasma arc.
There are no warning puffs of air. If the
0-50-2 fault code does not go off, send a
STOP signal from the CNC to remove the
fault.
Mini machine torch: This fault code is not
applicable to the mini machine torch.
0-51-0
Yellow
Yellow
The plasma power supply
was receiving a signal to start
cutting at the same time that
the power switch was set to
ON (I).
With a machine torch, this
condition is sometimes
referred to as a “stuck start.”
This fault code stops the system from operating.
Do the following. A quick restart is necessary.
Hand torch: The torch trigger was being
held in the “fire” position when the power
switch on the plasma power supply was set
to ON (I). Release the trigger and do a
quick restart of the plasma power supply.
Machine torch: The plasma power supply
was receiving a Start signal when the power
switch was set to ON (I). Set the start
signal to off, and do a quick restart of the
plasma power supply.
0-52-0
Yellow
Yellow
The torch is not connected. This fault code stops the system from operating.
Do the following. A quick restart is necessary.
Make sure that the torch lead is correctly
connected to the FastConnect receptacle
on the front of the plasma power supply. Do
a quick restart.
Fault
code
Fault
icon
Fault
LEDs Description Solutions

Table of Contents

Other manuals for Hypertherm SYNC Powermax 85

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm SYNC Powermax 85 and is the answer not in the manual?

Hypertherm SYNC Powermax 85 Specifications

General IconGeneral
BrandHypertherm
ModelSYNC Powermax 85
CategoryWelding System
LanguageEnglish

Related product manuals