116 MX3630-01 Rev. J SlideDriver/SlideDriver 50VF Series © 2019 www.hysecurity.com
Type Alert/Fault/Error Display Buzzer Chirp Sequence
Possible Cause &
Suggested Corrective
Action
Solutions
ERROR ERROR 1
Direction Error
3 chirps per second once per
minute
Close Limit tripped after running
Open or Open Limit tripped
after running Closed.
Assess cables and wire
connections.
• Make sure wires are connected
to the proper terminals.
Make sure gate handing is
appropriate.
• Swap connections of hydraulic
hoses, if necessary.
See Gate Handing on page
28.
ERROR ERROR 2
IES Disconnect
3 chirps per second once per
minute
• The IES sensor could be bad,
check to see that the NC
contact is intact.
• Check that you have the
most current sensor; visit our
website and view the technical
bulletins in the Tech Support
area. The sensor wire could be
loose; you may want to tighten
the female connectors with
some pliers.
• Verify the version of the
software by pressing the Reset
button. The software version
appears on the display. Make a
note of it. The software version
should be h4.53 or h5.54 (or
later).
• If necessary, update the
software using a PC laptop
and S.T.A.R.T. Register and
login in at www.hysecurity.com
ERROR ERROR 3
Hy5 COMM ERROR
3 chirps per second once per
minute
Caused by HY-5B removal or
lack socket connection integrity.
Message indicates which
detector alert applies to: Exit
Loop (ELD), Inside Obstruction
Loop (IOLD), Outside
Obstruction Loop (OOLD), or
Center Loop (CLD).
1. Press RESET.
2. Remove and reinstall
HY-5B.
3. Replace HY-5B, if needed.