76 MX3630-01 Rev. J SlideDriver/SlideDriver 50VF Series © 2019 www.hysecurity.com
Setting Performance Description Wire
Connection
6 Gate Lock output Controls external solenoid locks or magnetic locks. In both
directions of travel, this output is activated about 7/10ths of a
second before operator starts moving the gate.
Relay 1, 2 or 3
7 Gate forced open output Activated if gate is forced off closed limit switch and
operator is not able to restore gate to full closed position
within four seconds. The buzzer resets itself in 30 seconds
but relay stays active until gate receives a run command.
Relay 1, 2 or 3
8 Gate open too long output Activates when gate is open longer than the user-selected
period of time. Adjustable from a 0 second to 135 seconds
delay in 15-second increments.
NOTE:TL - OPEN TIME ALERT adjustments can be made in
Installer\ Menu.
Relay 1, 2 or 3
9 Safety Mode Alert output Activated when system is in Safety Mode or Entrapment
Mode. Safety Mode occurs upon an impact with an
obstruction. Entrapment Mode means gate is stopped and
occurs if inherent entrapment sensor triggers while system is
in Safety Mode.
Relay 1, 2 or 3
10 Entrapment Mode Alert output Activated only when system is in Entrapment Mode. Relay 1, 2 or 3
11 Unauthorized Vehicle Entry output
(Tail gate alert)
Activated when a second vehicle enters from outside without
a valid input from an access control device. The OOLD and
IOLD loops must be capable of being triggered at the same
time for this relay to ever activate. This output releases when
an access control input signals open or gate reaches the
close limit position.
Relay 1, 2 or 3
12 Outside Obstruction Vehicle
Detector output
This output is active whenever Outside Obstruction Loop
Detector is tripped. Interlocks an entry device to prevent
pedestrian use.
Relay 1, 2 or 3
13 Loitering Alert Indicates vehicle is loitering on Outside Obstruction Loop
with the gate closed. Adjustable from a 0 second to 135
second delay in 15-second intervals.
NOTE: LT
LOITERING ALERT adjustments can be made in
the Installer Menu.
Relay 1, 2 or 3
14 Gate nearing full travel output
(Nearing Limit)
Activated when gate is approaching full open or full closed.
Relay activates three feet from where software expects limit
switch to be triggered whether moving toward full open, full
close, or in a reverse travel mode.
Relay 1, 2 or 3
15 Gate failure output
(Fault mode alert)
Activated to report occurence of problem. Indicates the
system is in an Error, Fault, Alert, or Entrapment Mode. If
active, gate is disabled.
Relay 1, 2 or 3
16 Motor Running output Active when motor is running and gate is in motion. Relay 1, 2 or 3
17 AC Power Failure output This relay is normally energized and drops with loss of AC
power.
Relay 1, 2 or 3
18 DC Power Failure output
(Low battery alert)
Activated when battery power is very low, but output ceases
when battery is dead (18 volts). Relay is triggered when
battery is less than 21 volts.
Relay 1, 2 or 3
19 Flasher Relay Controls ashing lights to pulse once per second. Relay
is constantly pulsing except when open limit switch is
triggered. Recommended to
use User Relay 3 since it is an electronic relay
Relay 1 or 2*
(Relay 3)
20 Free Exit Loop Vehicle Detector
output
Active when the Free Exit Loop is tripped. Relay 1, 2 or 3

Table of Contents

Other manuals for HySecurity SlideDriver 50 VF Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HySecurity SlideDriver 50 VF Series and is the answer not in the manual?

HySecurity SlideDriver 50 VF Series Specifications

General IconGeneral
BrandHySecurity
ModelSlideDriver 50 VF Series
CategoryGate Opener
LanguageEnglish

Related product manuals