DIGITAL jGUN SAFETY BUTTON
The Directional Control Selector Button must rst be
pushed in the desired direction (clockwise or counter-
clockwise) before the trigger can be depressed. This
safety feature reduces the chance for operator error.
Personal Protective Equipment
• Always wear the appropriate personal protective equipment when operating a Digital jGun
including gloves, impact resistant eye protection, hearing protection, hard hat, and safety shoes.
The grade of protection required should be assessed for each use.
Air Supply Requirements
• The air supply line must be ½-inch minimum diameter to allow adequate air ow to the
Digital jGun.
• The air supply must provide a minimum of 90 psi at 50 cfm.
• Ensure that air line ttings are tight and leak free. Do not over tighten air line ttings.
• Open the air supply connected to the Digital jGun unit and run the Digital jGun while setting the
torque on the display.
IMPORTANT LI-ION BATTERY
INSTRUCTIONS
The Digital jGun contains a non-removable rechargeable Li-Ion Battery that powers the Display Elec-
tronics. The following instructions, concerning the Li-Ion Battery shall be followed:
• DO NOT splash or immerse in water or other liquids.
• Do not incinerate the battery even if it is severely damaged or is completely worn out. The
battery can explode in a re. Toxic fumes and materials are created when lithium ion batteries are
burned.
• Do not charge or use the battery in explosive atmospheres, such as in the presence of
flammable liquids, gases or dust. Inserting or removing the charger may ignite dust or fumes.
• If battery contents come into contact with the skin, immediately wash area with mild soap
and water.
• If battery liquid gets into the eyes, rinse over the open eye for 15 minutes or until irritation
ceases. If medical attention is needed, the battery electrolyte is composed of a mixture of
liquid organic carbonates and lithium salts.
• Contents of opened battery cells may cause respiratory irritation. Provide fresh air. If
symptoms persist, seek medical attention.