v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, Type 8863,” on page 93 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only)”, that step must be performed only by a
trained service technician.
Error code Description Action
175 Bad EEPROM CRC#1.
1. Restart the server.
2. Update the BMC firmware (see “Updating the
firmware” on page 133).
3. Reseat the microprocessor tray.
4. (Trained service technician only) Replace the
microprocessor tray.
178 System VPD not available.
1. Restart the server.
2. Update the BMC firmware (see “Updating the
firmware” on page 133).
3. Reseat the microprocessor tray.
4. (Trained service technician only) Replace the
microprocessor tray.
184 Power-on password damaged.
1. Run the Configuration/Setup Utility program,
select Load Default Settings, and save the
settings.
2. Reseat the following components:
a. Battery
b. I/O board
3.
Replace the components listed in step 2 one at a
time, in the order shown, restarting the server
each time.
187 VPD serial number not set.
1. Set the serial number by updating the BIOS code
level (see “Updating the firmware” on page 133).
2. Reseat the following components:
a. I/O board
b. Optional Remote Supervisor Adapter II
SlimLine
3.
Replace the components listed in step 2 one at a
time, in the order shown, restarting the server
each time.
188 Bad EEPROM CRC #2.
1. Restart the server.
2. Update the BMC firmware (see “Updating the
firmware” on page 133).
3. Reseat the microprocessor tray.
4. (Trained service technician only) Replace the
microprocessor tray.
189 An attempt was made to access the server
with an incorrect password.
Restart the server and enter the administrator
password; then, run the Configuration/Setup Utility
program and change the power-on password.
22 IBM xSeries 366 Type 8863: Problem Determination and Service Guide

Table of Contents

Other manuals for IBM 8863 - eServer xSeries 366

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM 8863 - eServer xSeries 366 and is the answer not in the manual?

IBM 8863 - eServer xSeries 366 Specifications

General IconGeneral
BrandIBM
Model8863 - eServer xSeries 366
CategoryDesktop
LanguageEnglish

Related product manuals