v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, “Parts listing, Types 7871 and 1949,” on page 41 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
Trained service technician.
Error code Description Action
0058004 Mirror failover complete.
1. Make sure that the DIMMs are installed in the
proper sequence (see “Installing a memory
module” on page 64).
2. Reseat the DIMMs and restart the server (see
“Removing a memory module” on page 63 and
“Installing a memory module” on page 64).
3. Remove each DIMM one at a time, restarting the
server after removing each DIMM until the error
is gone (see “Removing a memory module” on
page 63).
4. Replace the failed DIMM; then, reinstall the
DIMMs to their original connectors and restart
the server (see “Installing a memory module” on
page 64).
5. (Trained service technician only) Replace the
system board (see “Removing the system-board
assembly” on page 94 and “Installing the
system-board assembly” on page 95).
0058006 Spare copy failover complete.
1. Make sure that the DIMMs are installed in the
proper sequence (see “Installing a memory
module” on page 64).
2. Reseat the DIMMs and restart the server (see
“Removing a memory module” on page 63 and
“Installing a memory module” on page 64).
3. Remove each DIMM one at a time, restarting the
server after removing each DIMM until the error
is gone (see “Removing a memory module” on
page 63).
4. Replace the failed DIMM; then, reinstall the
DIMMs to their original connectors and restart
the server (see “Installing a memory module” on
page 64).
5. (Trained service technician only) Replace the
system board (see “Removing the system-board
assembly” on page 94 and “Installing the
system-board assembly” on page 95).
0058007 Unsupported DIMM population
1. Reseat the DIMMs and restart the server (see
“Removing a memory module” on page 63 and
“Installing a memory module” on page 64).
2. Make sure that the DIMMs are installed in the
proper sequence (see “Installing a memory
module” on page 64).
152 BladeCenter HS22V Type 7871 and 1949: Problem Determination and Service Guide