Repeat the previous service procedure and swap out the mismatched PSU once the replacement PSU
is received.
Note: It is not recommended to use mismatched PSUs in a 5147-102 enclosure.
Miscellaneous equipment specication (MES) instructions
An IBM Elastic Storage System 5147-102 Storage Enclosure hardware change can be done by using the
MES instructions.
Upgrading an IBM Elastic Storage System 5147-102 Storage Enclosure from
a half-populated to a fully populated conguration
This non-concurrent MES procedure involves shifting down customer workload, adding 50 more HDDs
to an existing IBM Elastic Storage System 5147-102 Storage Enclosure to ll up all 102 drive slots with
HDDs, and returning the system to the customer for conguration of the new storage.
This procedure is only applicable to an IBM Elastic Storage System solution with a single half-populated
IBM Elastic Storage System 5147-102 Storage Enclosure.
MES upgrade steps
Refer to the following steps to upgrade an 5147-102 from a half-populated to a fully populated
conguration:
1. Customer task: Stop using the ESS 5147-102 enclosure.
2. Customer task: Unmount affected le systems that are mounted on the ESS 5147-102 enclosure and
shutdown GPFS.
mmshutdown -a
3. Identify the ESS 5147-102 storage enclosure to be upgraded.
a. Perform the following checks in the essutils menu and gather ESS 5147-102 serial number in
the SSR Checks for ESS 3500 nodes’ section:
i) Quick storage conguration check
ii) Check enclosure cabling and paths to disks
b. SSR Checks for ESS 3500 nodes > 1. Quick storage conguration check.
/opt/ibm/ess/tools/bin/essstoragequickcheck -N localhost
[INFO] Start of storage quick configuration check
[INFO] nodelist: localhost
[INFO] Checking node: localhost
[INFO] IO Server/Canister Type: ESS3500-5141-FN2, Serial: 78E400QB
[OK] Valid SAS Adapter Configuration. Number of Adapter(s) found: 1
[INFO] Slots of SAS Adapter found 41:00.0,
[OK] Valid Network Adapter Configuration. Number of Adapter(s) found: 2
[INFO] Slots of Network Adapter found 08:00.1, c1:00.0, c1:00.1, 08:00.0
[OK] NVMe Drv 15.36TB NVMe Tier-1 Flash found 24
[OK] Summary: total NVMe Drv found 24, expected NVMe Drv 24
[INFO] Found only Rotating disks inside enclosure.
[INFO] Enclosure 5147-102 found 1
[INFO] Disk ST10000NM0578 E found 52
[OK] Total disk found 52, expected 52
[INFO] Total ssd found 0, expected 0
[INFO] End of storage quick configuration check
[OK] essstoragequickcheck passed successfully
Press Enter to continue...
SSR Checks for ESS 3500 nodes > 2. Check enclosure cabling and paths to disks
/opt/ibm/ess/tools/bin/essfindmissingdisks -N localhost
[INFO] Start find missing disk paths
[INFO] nodelist: localhost
[INFO] May take long time to complete search of all drive paths
6
IBM Elastic Storage System 5147-10 Storage Enclosure: Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Elastic Storage System 5147-102 and is the answer not in the manual?

IBM Elastic Storage System 5147-102 Specifications

General IconGeneral
BrandIBM
ModelElastic Storage System 5147-102
CategoryEnclosure
LanguageEnglish

Related product manuals