Table 11. Temperature requirements
Environment
Ambient
temperature
Altitude Relative humidity
Maximum dew
point
Operating 10° C to 35° C (50°
F to 95° F)
0 - 3050 m (0 -
10,006 ft)
20% to 80% non-condensing 21°C (69° F)
Non-operating -10° C to 50° C (14°
F to 125° F)
0 - 3050 m (0 -
10,006 ft)
8% to 80% non-condensing 27°C (80° F)
Storage 1° C to 60° C (33° F
to 140° F)
No limit 5% to 80% non-condensing 29°C (84° F)
Shipping -40° C to 60° C
(-40° F to 140° F)
No limit 5% to 100% non-condensing 29°C (84° F)
Physical characteristics
Table 12 on page 8 summarizes the dimension and weight information for the FlashSystem 5000
control and expansion enclosures. Ensure that the rack has enough available space to support each type
of enclosure.
Table 12. Enclosure physical characteristics
Enclosure type Model Height Width Depth Maximum weight
Drive ready
(without
drives)
Fully
congured
(with drives)
Control
enclosures (12
LFF drive slots)
FlashSystem
5010
( 2072-2H2 )
FlashSystem
5030
( 2072-3H2 )
FlashSystem
5010 (2072-
S12)
FlashSystem
5030 (2072-
T12)
8.7 cm (3.4 in) 48.3 cm (19.0
in)
55.6 cm (21.9
in)
18.0 kg (39.6
lb)
28.3 kg (62.2
lb)
Control
enclosures (24
SFF drive slots)
FlashSystem
5010
( 2072-2H4 )
FlashSystem
5030
( 2072-3H4 )
FlashSystem
5010 (2072-
S24)
FlashSystem
5030 (2072-
T24)
8.7 cm (3.4 in) 48.3 cm (19.0
in)
55.6 cm (21.9
in)
19.0 kg (41.8
lb)
27.3 kg (60.0
lb)
8 IBM FlashSystem 5000 : FlashSystem 5000 Quick Installation Guide