Table 23. SMART ASC/ASCQ error codes and messages (continued)
ASC ASCQ Description
5D 10 HARDWARE IMPENDING FAILURE GENERAL HARD DRIVE
FAILURE
5D 11 HARDWARE IMPENDING FAILURE DRIVE ERROR RATE TOO HIGH
5D 12 HARDWARE IMPENDING FAILURE DATA ERROR RATE TOO HIGH
5D 13 HARDWARE IMPENDING FAILURE SEEK ERROR RATE TOO HIGH
5D 14 HARDWARE IMPENDING FAILURE TOO MANY BLOCK REASSIGNS
5D 15 HARDWARE IMPENDING FAILURE ACCESS TIMES TOO HIGH
5D 16 HARDWARE IMPENDING FAILURE START UNIT TIMES TOO HIGH
5D 17 HARDWARE IMPENDING FAILURE CHANNEL PARAMETRICS
5D 18 HARDWARE IMPENDING FAILURE CONTROLLER DETECTED
5D 19 HARDWARE IMPENDING FAILURE THROUGHPUT PERFORMANCE
5D 1A HARDWARE IMPENDING FAILURE SEEK TIME PERFORMANCE
5D 1B HARDWARE IMPENDING FAILURE SPIN-UP RETRY COUNT
5D 1C HARDWARE IMPENDING FAILURE DRIVE CALIBRATION RETRY
COUNT
5D 20 CONTROLLER IMPENDING FAILURE GENERAL HARD DRIVE
FAILURE
5D 21 CONTROLLER IMPENDING FAILURE DRIVE ERROR RATE TOO
HIGH
5D 22 CONTROLLER IMPENDING FAILURE DATA ERROR RATE TOO
HIGH
5D 23 CONTROLLER IMPENDING FAILURE SEEK ERROR RATE TOO
HIGH
5D 24 CONTROLLER IMPENDING FAILURE TOO MANY BLOCK
REASSIGNS
5D 25 CONTROLLER IMPENDING FAILURE ACCESS TIMES TOO HIGH
5D 26 CONTROLLER IMPENDING FAILURE START UNIT TIMES TOO
HIGH
5D 27 CONTROLLER IMPENDING FAILURE CHANNEL PARAMETRICS
5D 28 CONTROLLER IMPENDING FAILURE CONTROLLER DETECTED
5D 29 CONTROLLER IMPENDING FAILURE THROUGHPUT
PERFORMANCE
5D 2A CONTROLLER IMPENDING FAILURE SEEK TIME PERFORMANCE
5D 2B CONTROLLER IMPENDING FAILURE SPIN-UP RETRY COUNT
5D 2C CONTROLLER IMPENDING FAILURE DRIVE CALIBRATION RETRY
COUNT
5D 30 DATA CHANNEL IMPENDING FAILURE GENERAL HARD DRIVE
FAILURE
5D 31 DATA CHANNEL IMPENDING FAILURE DRIVE ERROR RATE TOO
HIGH
5D 32 DATA CHANNEL IMPENDING FAILURE DATA ERROR RATE TOO
HIGH
5D 33 DATA CHANNEL IMPENDING FAILURE SEEK ERROR RATE TOO
HIGH
Chapter 4. File module 73

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 2076-224 and is the answer not in the manual?

IBM Storwize V7000 2076-224 Specifications

General IconGeneral
Model2076-224
Maximum Drives240
RAID Levels0, 1, 5, 6, 10
Form Factor2U
Drive InterfaceSAS
ConnectivityFibre Channel, iSCSI
Drive Bays24
Host Interface8 Gbps Fibre Channel, 1 Gbps iSCSI
Power SupplyDual redundant power supplies
Operating Temperature10°C to 35°C (50°F to 95°F)
Operating Humidity20% to 80% non-condensing
Non-operating Humidity10% to 90% non-condensing