4.0 Environmental Specifications
4.1 Temperature/Humidity Limits
Condition Temp Limits (Dry Bulb) Relative Humidity Max. Wet Bulb Temp
Operating / Standby 5 to 40° 8 to 80 % 27°C
Storage (packaged) 0 to 60°C 5 to 80 % 29°C
Shipment (packaged) -40 to 60°C 5 to 100 % 29°C
4.2 Altitude Limits
The product is designed to operate up to 3050 meters (10,000 feet).
4.3 Power
Off (attached to mains) 4W
Suspend Not supported
Standby 80W
On (idle) 120W
Power Consumption
(system)
On (max) 170W
Input Voltage
100 - 127, 200 - 240 VAC (nominal), 50 or 60 Hz (+/- 3 Hz)
Sinusoidal, trapezoidal, or square wave inputs
kVA 0.3
AC Input Connector/Cable IEC 320 C14, unshielded right angle type
Leakage current 3.5 mA maximum
Inrush < 30 A (peak, first cycle)
4.4 Acoustics
Measurement Operator -Idle
LwAu (bels) 5.0
All measurements made in accordance with ISO 7779 and reported in conformance with ISO 9296.
4.5 Standards Compliance
4.5.1 Product Certifications
Category Standard
External Safety
IEC 60950-1 1
st
Edition with all national deviations
UL 60950-1 1
st
Edition
CAN/CSA C22.2 No. 60950-1 3
rd
Edition
CCC (China)
IRAM (Argentina)
PSE (Japan)
GOST (Russia)
BSMI (Taiwan)
Electrostatic Discharge (ESD) EN 55024:1998 (EN 61000-4-2:1995)