v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, “Parts listing, Type 4364, 4365, or 4366 server,” on page 15 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
System-event/error log message Action
DHCP failure, no IP@ assigned-RETRYING!,
rc=xxx, count=yyy
Information only.
Dialback failed for userid x. Could not connect at
phone number yyy yyy yyyy
Information only.
ENET[eee] DHCP-HstNme=a, DN=b,
IP@=ccc.ccc.ccc.ccc GW@=ddd.ddd.ddd.ddd,
NMsk=fff.fff.fff.fff, DNS1@=ggg.ggg.ggg.ggg,
DNS2@=hhh.hhh.hhh.hhh
Information only.
ENET[eee] IP-Cfg: HstName=x,
IP@=ccc.ccc.ccc.ccc, GW@=ddd.ddd.ddd.ddd,
NetMsk=fff.fff.fff.fff
Information only.
Failure reading an I2C device, possible bus
failure.
1. Reseat the following components:
a. AC power cord
b. (Trained service technician only) System board
c. Power supply
2. (Trained service technician only) Replace the system board.
Fan x Outside Recommended Speed.
1. Make sure that fan x is not obstructed.
2. Reseat the following components:
a. Fan x
b. Fan x cable
3. Replace fan x.
Fan x Failure
1. Make sure that fan x is not obstructed.
2. Reseat the following components:
a. Fan x
b. Fan x cable
3. Replace fan x.
Flash of x via y failed for user z...z Information only.
Flash of x by y via z was successful...w Information only.
Flash succeeded for x (address : y) Information only.
Hard drive x removal detected. Reseat hard disk drive x and restart the server.
Hard drive x fault
1. Run the diagnostic programs.
2. Replace hard disk drive x.
3. Replace the hard disk drive backplane or back plate.
Internal error CPU fault Information only. If the message remains:
1. (Trained service technician only) Reseat the microprocessor.
2. (Trained service technician only) Replace the microprocessor.
Invalid userid or password received. Userid is x Information only.
LAN: Command mode tamper triggered.
Possible break-in attempt
Information only.
106 IBM System x3250 Types 4364, 4365, and 4366: Problem Determination and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3250 4364 and is the answer not in the manual?

IBM System x3250 4364 Specifications

General IconGeneral
Form Factor1U Rack
MemoryUp to 8 GB
ProcessorIntel Xeon 3040
Memory TypeDDR2
StorageUp to 1.5TB
Storage ControllerIntegrated SATA
RAID SupportRAID 0, 1
Operating System SupportWindows Server, Linux
Processor CoresDual-Core