f. Turn on the server. If the server does not start, see “Troubleshooting tables”
on page 81.
g. Check the system-error LED on the operator information panel. If it is
flashing, check the LEDs on the system board (see “System-board LEDs” on
page 92).
h. Check for the following results:
v Successful completion of POST (see “POST” on page 67 for more
information)
v Successful completion of startup
3. Did one or more beeps sound?
v No: Find the failure symptom in “Troubleshooting tables” on page 81; if
necessary, run the diagnostic programs (see “Running the diagnostic
programs” on page 94).
– If you receive an error, see “Diagnostic error codes” on page 96.
– If the diagnostic programs were completed successfully and you still
suspect a problem, see “Solving undetermined problems” on page 114.
v Yes: Find the beep code in “POST beep codes” on page 67; if necessary,
see “Solving undetermined problems” on page 114.
80 IBM System x3250 Types 4364, 4365, and 4366: Problem Determination and Service Guide