v ServeRAID H1110 adapter: Take the signal cable that is attached to the
drive backplane for drive bays 0 through 3 and connect it to the SAS/SATA
connector on the ServeRAID adapter.
v ServeRAID M1115 adpater: Take the signal cable that is attached to the
drive backplane for drive bays 4 through 7 and connect it to the ServeRAID
adapter connector for drive bays 4 through 7 (port 1). Connect the other
signal cable that is attached to the drive backplane for drive bays 0 through 3
and connect it to the other connector (port 0) on the adapter.
v ServeRAID M5110 adapter: Take the signal cable that is attached to the
drive backplane for drive bays 4 through 7 and connect it to the ServeRAID
adapter connector for drive bays 4 through 7 (port 1). Connect the other
signal cable that is attached to the drive backplane for drive bays 0 through 3
and connect it to the other connector (port 0) on the adapter.
74 IBM System x3550 M4 Type 7914: Installation and User’s Guide