To  run  ServeRAID  Manager  in  Startable  CD  mode,  turn  on  the  server;  then,  insert 
the  CD  into  the  CD-RW/DVD  drive.  If  ServeRAID  Manager  detects  an  unconfigured 
controller  and  ready  drives,  the  Configuration  wizard  starts. 
In  the  Configuration  wizard,  you  can  select  express  configuration  or  custom 
configuration.  Express  configuration  automatically  configures  the  controller  by 
grouping  the  first  two  physical  drives  in  the  ServeRAID  Manager  tree  into  an  array 
and  creating  a  RAID  level-1  logical  drive.  If  you  select  custom  configuration,  you 
can  select  the  two  physical  drives  that  you  want  to  group  into  an  array  and  create  a 
hot-spare  drive. 
Using  express  configuration:  To  use  express  configuration,  complete  the 
following  steps: 
1.  In  the  ServeRAID  Manager  tree,  click  the  controller. 
2.  Click  Express  configuration. 
3.  Click  Next. 
4.  In  the  “Configuration  summary”  window,  review  the  information.  To  change  the 
configuration,  click  Modify  arrays. 
5.  Click  Apply;  when  you  are  asked  whether  you  want  to  apply  the  new 
configuration,  click  Yes.  The  configuration  is  saved  in  the  controller  and  in  the 
physical  drives. 
6.  Exit  from  ServeRAID  Manager  and  remove  the  CD  from  the  CD-RW/DVD  drive. 
7.  Restart  the  server.
Using
  custom  configuration:  To  use  custom  configuration,  complete  the 
following  steps: 
 
1.  In  the  ServeRAID  Manager  tree,  click  the  controller. 
 
2.  Click  Custom  configuration. 
 
3.  Click  Next. 
 
4.  In  the  “Create  arrays”  window,  from  the  list  of  ready  drives,  select  the  drives 
that  you  want  to  group  into  the  array. 
 
5.  Click  the  (Add  selected  drives)  icon  to  add  the  drives  to  the  array. 
 
6.  If  you  want  to  configure  a  hot-spare  drive,  complete  the  following  steps: 
a.  Click  the  Spares  tab. 
b.  Select  the  physical  drive  that  you  want  to  designate  as  the  hot-spare  drive, 
and  click  the  (Add  selected  drives)  icon.
  7.  Click  Next. 
 
8.  Review  the  information  in  the  “Configuration  summary”  window.  To  change  the 
configuration,  click  Back. 
 
9.  Click  Apply;  when  you  are  asked  whether  you  want  to  apply  the  new 
configuration,  click  Yes.  The  configuration  is  saved  in  the  controller  and  in  the 
physical  drives. 
10.  Exit  from  ServeRAID  Manager  and  remove  the  CD  from  the  CD-RW/DVD 
drive. 
11.  Restart  the  server.
Viewing  the  configuration 
You  can  use  ServeRAID  Manager  to  view  information  about  RAID  controllers  and 
the  RAID  subsystem  (such  as  arrays,  logical  drives,  hot-spare  drives,  and  physical 
 
44  IBM  System  x3650  Type  7979:  Installation  Guide