EasyManua.ls Logo

ICM Controls SC 3001 - Testing the Thermostat

ICM Controls SC 3001
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
Note: Once the thermostat is installed, it should be thoroughly tested.
CAUTION!
:
Do not energize the air conditioning system when the outdoor temperature is below
50 degrees. It can result in equipment damage or personal injury.
1. Move the Fan Auto/On switch to the Auto position.
Cool Test
1. Slide Cool/Off/Heat switch to Cool position. Cool mode screen is displayed.
2. Adjust set temperature so it is 5 degrees below room temperature.
3. Air conditioning should come on within a few seconds.
4. Adjust the set temperature 2 degrees above the room temperature and
the A/C should turn off. There may be a fan delay on your system.
Note: There is a four-minute delay to protect your compressor.
Heat Test
1. Slide Cool/Off/Heat switch to Heat position. Heat mode screen is displayed.
2. Adjust the set temperature so it is 5 degrees above the room temperature.
3. Heat should come on within a few seconds.
4. Adjust the set temperature so it is 2 degrees below the room temperature
and the heat should turn off. There may be a fan delay on your system.
Note: For heat pumps, there is a four-minute delay to protect your
compressor.
(Testing continued on Page 10)