98
12
CONNECTIONS AND MAINTENANCE
MB-75/MB-132 installation
An optional MB-75/MB-132 f l u s h m o u n t Kit is available for
mounting the transceiver to a flat surface such as an instru-
ment panel.
KEEP the transceiver and microphone at least 1 meter
away from the vessel’s magnetic navigation compass.
q Using the template on page 107, carefully cut a hole into
the instrument panel, or wherever you plan to mount the
transceiver.
w Slide the transceiver through the hole, as shown below.
D MB-75 installation
q Attach the 2 supplied bolts (M5 × 8 mm) on either side of
the transceiver.
w Attach the clamps on either side of the transceiver.
•Make surethat the clampsalignparallel tothetransceivers
body.
w
w
Clamp
Supplied bolt
e Tighten the end bolts on the clamps (rotate clockwise) so
that the clamps press firmly against the inside of the in-
strument control panel. (Torque: 0.6 Nm)
r Tighten the locking nuts (rotate counterclockwise) so that
the transceiver is securely mounted in position as below.
t Connect the antenna and power cable, then return the in-
strument control panel to its original place.