109
16
TROUBLESHOOTING
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
PROBLEM POSSIBLE CAUSE SOLUTION REF.
The transceiver does
not turn ON.
•Badconnectiontothepowersupply. •Checktheconnectiontothetransceiverand
power supply.
p. 95
Little or no sound comes
from the speaker.
•Squelchlevelissettoohigh.
•Volumelevelissettoolow.
•Speakerhasbeenexposedtowater.
•Setthesquelchtothethresholdpoint.
•Setthevolumetoasuitablelevel.
•RemovethewaterwiththeAquaQuakefunc-
tion.
p. 3
p. 3
p. 14
Transmitting is impossi-
ble, or high power can-
not be selected
.
•Some channels are programmed for low
power or receive only by regulations.
•Theoutputpowerissettolow.
•Changechannels.
•Push[HI/LO]toselecthighpower.
pp. 9,
10
p. 11
Scan does not start. More than 2 favorite channels are not pro-
grammed.
•Set thedesired channelsasFavoritechan-
nels.
p. 16
No beep sounds. •BeeptonesareturnedOFF. •TurnthebeeptonesONintheCONFIGURA-
TION menu.
p. 86
Distress calls cannot be
transmitted.
•MMSI (DSC self ID) code is not pro-
grammed.
•ProgramtheMMSI(DSCselfID)code. p. 7
Does not record or does
not record properly.
•ThememoryICisnotworking. •ThememoryICshouldbereplaced.
Ask your service center or technical dealer
for details.