TM 10-7360-226-13&P
CONTAINERIZED KITCHEN (CK) 0016 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES
0016 00-8
Table 2. During Operation PMCS for CK – Continued
ITEM
NO.
INTERVAL MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE EQUIPMENT
NOT READY/
AVAILABLE IF:
6 During Refrigerators Inspect door for proper seal contact.
Check inside thermometer for proper
temperature. Check operation of
interior light.
Door not properly
sealing. Will not
maintain proper
temperature.
7 During ECU Monitor for proper operation and
excessive or unusual noise. Inspect
filters and clean as necessary.