5 - 3
5-2 SOFTWARE ADJUSTMENT (FREQUENCY ADJUSTMENTS)
1) Select an adjustment item using [
]/[
] on the PC's keyboard.
2) Set or modify the adjustment value as specifi ed using [
]/[
] on the PC's keyboard, and then push [ENTER].
• I/O Check window
(The values shown above are exsample only.
Each transceiver has own values.)
Lock voltage
appears here
* * *
ADJUSTMENT ADJUSTMENT CONDITION
MEASUREMENT
VALUE
UNIT OPERATION
PLL LOCK
VOLTAGE
(Verify)
1 • Operating CH. : 16
• Receiving
PC
screen
Click the "I/O check button"
on the ADJ-M73's screen (see
page 5-3) to open the I/O check
window as below.
1.55–2.65 V
(Verify)
2 • Operating CH. : 16
Connect a dummy load or RF power
meter to the antenna connector.
• Transmitting
REFERENCE
FREQUENCY
[Ref Freq]
1 • Operating CH. : 16
Connect the RF power meter or a 50
Ω
dummy load to the antenna connector.
• Transmitting
Top
Panel
Loosely couple the frequency
counter to the antenna conector.
156.8000 MHz