5-5
5-4 TRANSMIT ADJUSTMENTS (CONTINUED)
ADJUSTMENT
ADJUSTMENT ITEM
DISPLAY
SETTING CONDITION OPERATION
TX OUTPUT
POWER (MF)
- Adjustment -
1 “TX Total MF Gain” • Receiving
Push
.
2 “TX Total MF Gain”
• Automatically transmits. Rotate [CH/GRP] to set the output
power to 70 W, then push .
(Two beeps sound.)
3 “Power Tune (2.1M)” Rotate [CH/GRP] to set the output
power to 10 W, then push
.
(Two beeps sound.)
4 “Power 20W (2.1M)” Rotate [CH/GRP] to set the output
power to 20 W, then push
.
(Two beeps sound.)
5 “Power 60W (2.1M)” Rotate [CH/GRP] to set the output
power to 70 W, then push
.
(Two beeps sound.)
6 “Power 100W (2.1M)” Rotate [CH/GRP] to set the output
power to 100 W, then push
.
(Two beeps sound.)
7 “Power 150W (2.1M)” Rotate [CH/GRP] to set the output
power to 140 W, then push
.
(Two beeps sound, and then
automatically moves to the ALC
adjustment “ALC.”)
8 “Power 150W (1.6M)”
ALC
- Adjustment -
1 “ALC” • Automatically transmits.
Push
.
(Three seconds later, two beeps
sound and then automatically
enters to the Drive gain adjustment
“Drive Min (12M)” mode.)
DRIVE GAIN
- Adjustment -
1 “Drive Min (12M)” • Automatically transmits.
Push
.
(Ten seconds later, two beeps
sound and then automatically
moves to the SWR adjustment
“SWR2.”)
SWR
- Preparation -
If a 100 Ω dummy load (or a dummy load with VSWR of 2:1) is unavailable, skip this adjustment.
1 “SWR2”
• Connect the 100 Ω dummy load to
the [ANT] connector.
–
- Adjustment -
2 “SWR2” • Automatically transmits.
Push
.
(Three seconds later, two beeps
sound and then automatically
moves to the Id APC adjustment
“ID-APC Check.”)
Id APC
- Adjustment -
1 “ID-APC Check” • Automatically transmits.
( Automatically returns to receive
when the beeps sound.)
Push
.
(Two seconds later, two beeps
sound and then automatically
returns to the adjustment menu.)