30
12
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION. REF.
The transceiver does
not turn ON.
• The battery is exhausted.
• Bad battery connection.
• Recharge the battery pack.
• Remove and reattach the battery.
p. 22
p. 5
No sound from speaker. • Squelch level is too deep.
• Volume level is too low.
• Speaker has been exposed to water.
• Set squelch to the threshold point.
• Set [VOL] to a suitable level.
• Drain water from the speaker.
p. 11
p. 10
Transmitting is impossi-
ble, or high power can
not be selected.
Some channels are for low power or receive
only.
• The battery is exhausted.
• The output power is set to low.
• Change channels.
• Recharge the battery pack.
• Push [H/L•
LOCK] to select high power.
pp. 8,
9, 31
p. 22
p. 10
The displayed channel
cannot be changed.
• Lock function is activated. Hold down [H/L•
LOCK] for 1 second to can-
cel the function.
p. 12
Scan does not start. • “TAG” channels are not programmed. Set the desired channels as “TAG” chan-
nels.
p. 14
No beeps. • Beep tones are turned OFF. Set the beep tones to ON (Fix Beep/User
Beep) in Set mode.
p. 18
Self check error.
(Temperature)
The temperature is outside of –35°C ~
+73 °C (–31°F ~ +163°F) (approximately)
Leave the transceiver at room temperature
for a while. Turn ON the power to check if
the internal temperature has returned to nor-
mal.
Self check error.
(Battery voltage)
The connected battery pack’s voltage is
more than 8.8 V.
Verify the battery voltage is correct.
Self check error.
(Water intrusion)
Water has entered the transceiver. Have the transceiver checked at your local
distributor or dealer to see whether the trans-
ceiver works properly or not.