PROBLEM POSSIBLE CAUSE SOLUTION REF.
POWER
Power does not come on
when the [POWER] switch
is pushed.
• DC power cable is improperly connected.
• Fuse is blown.
• Reconnect the DC power cable correctly.
• Check for the cause, then replace the fuse with
a spare one.
(Fuses are installed in the DC power cable
and the internal MAIN unit.)
—
p. 37
RECEIVE
No sound comes from the
speaker.
• Volume level is too low.
• The squelch is closed.
• Rotate [AF] clockwise to obtain a suitable
listening level.
• Rotate [RF/SQL] to 12 o’clock position to open
the squelch.
p. 2
p. 14
Sensitivity is low. • The antenna is not connected properly.
• The antenna for another band is selected.
• The attenuator is activated.
• Reconnect to the antenna connector.
• Select an antenna suitable for the operating
frequency.
• Push [ATT] to turn the function OFF.
—
p. 16
p. 16
Receive audio is distorted. • The operating mode is not selected correctly.
• PBT function is activated.
• Noise blanker function is activated.
• Preamp is activated.
• The optional noise reduction is activated and
the [NR] level is set too high.
• Select a suitable operating mode.
• Set [TWIN PBT] to the center position.
• Push [NB] to turn the function OFF.
• Push [P.AMP] once or twice to turn the function
OFF.
• Push [NR] to turn the function OFF.
p. 14
p. 15
p. 15
p. 16
p. 20
SCAN
Programmed scan does
not stop.
• Squelch is open.
• [RF/SQL] is assigned to RF gain control and
squelch is open.
• Set [RF/SQL] to the threshold point.
• Reset [RF/SQL] control assignment and set it to
the threshold point.
p. 14
pgs.
14, 30
Programmed scan does
not start.
• The same frequencies have been programmed
in scan edge memory channels P1 and P2.
• Program different frequencies in scan edge
memory channels P1 and P2.
p. 22
Memory scan does not
start.
• 2 or more memory channels have not been
programmed.
• Program 2 or more memory channels.
p. 22
Select memory scan does
not start.
• 2 or more memory channels have not been
designated as select channels.
• Designate 2 or more memory channels as select
channels for the scan.
p. 26
DISPLAY
“F.AGC” flashes in the
function display.
• A scan or band scope function is activated via
an optional RS-R75 remote control software.
• If these functions are not in use, push [AGC] to
deactivate the function.
—
The displayed frequency
does not change properly.
• The dial lock function is activated.
• The internal CPU has malfunctioned.
• Push [LOCK] to deactivate the function.
• Reset the CPU.
p. 13
See
below.