5
MAINTENANCE
Troubleshooting

Icom service center.
PROBLEM POSSIBLE CAUSE SOLUTION
REFERENCE
The repeater does not turn
ON.
The connector or DC power
cable has a poor contact.
The external power unit is
turned OFF.
Blown fuse.
Check the connector pins and then reconnect
the DC power cable.

Fix the problem, then replace the fuse.
p. 5
-
p. 12
Cannot turn OFF the repeater. You are not holding down
[POWER].
Hold down [POWER] until its green indicator
is turned OFF.
p. 2
Both [TX] and [RX] indicator
blink at same time.
The repeater settings are
reset to default.
Set operation frequency and tone. Ask dealer
for details.
The repeater does not
transmit output power, or
transmits low output power.
Antenna or coaxial cable
has problems.
Check, and if necessary, replace the coaxial
cable or the antenna connector.
-
Sensitivity is low and only
strong signals are heard.
Antenna or coaxial cable
has problems.
Check, and if necessary, replace the coaxial
cable or the antenna connector.
-
There was a problem with the
operation.
Caused by external factors
such as static electricity.
Turn OFF the repeater, remove and reattach
the external power unit, and then turn ON the
repeater.
-
The repeater does not repeat
the received signal.
Incorrect settings. Check the mode setting (FM or DV).
Check the operation frequency setting and
tone setting.
Check the callsign setting and IP address
setting.
Ask dealer
for details.
Cannot connect to other
repeater sites.
Cannot connect to the
Gateway server from the
WAN port.

enabled on your router.
-
The repeater does not
operate as a Gateway
The ID-RP2C is connected. Connect a Gateway server to the ID-RP2C. p. 1
Detaching the rack handle
You can detach the rack handle, depending on the

Allen wrench to detach, as shown below.