48
9 APPENDIX 1: PARAMETERS ENCODER
For more information related to the encoder, see 3.1 Material, p. 10 & 4.2 Factory setting, p. 16.
9.1 GENERAL
When the I-SAFE is powered on, de encoder display shows o. It means it is in « configuration » mode
and ready to communicate through Bluetooth, if the option is available.
After 15 seconds, the I-SAFE goes to « measure mode », with the parameters of the TAILOR MADE
ZONE 1. The encoder displays then and flashes every 5 seconds.
To choose one of the standard speed limits or another function, press the the settings encoder button
for 3 seconds. The settings encoder display stops blinking. You can then release the button.
The encoder display blinks again quickly. Then press the button to scroll through the menus (they
scroll in a loop). When the desired menu appears on the encoder, wait 3 seconds, the I-SAFE goes then
to the chosen function or menu.
For the menus « download statistics to USB stick » (d) and « upload param tailor made zone to the
unit » (P), the encoder display shows u. It means you can insert the USB stick into the USB port. The
I-SAFE reads then the data from the USB stick of or writes the measurement data. The dot next to the
u flashes. Don’t remove the stick while the dot next to the “u” flashes.
When the display shows d or P again, the stick can be unplugged
Press the button again for 3 seconds and release when the display stops flashing and choose the right
function. If you don’t choose a function or menu, the I-SAFE goes to « measure mode » after four
minutes with last chosen settings (by default, tailor made zone 1).
9.2 AVAILABLE FUNCTIONS
- = TAILOR MADE ZONE 1 (= zone 50 for units with factory setting)
= = TAILOR MADE ZONE 2
= TAILOR MADE ZONE 3
1 = ZONE 30
2 = ZONE 50
3 = ZONE 70
4 = ZONE 90
d = DOWNLOAD STATISTICS TO USB STICK
The I-SAFE must be powered and in “measure” or “demo” mode.
o Press the settings encoder button for 3 seconds.
o When the settings encoder display stops blinking, release the button.
o The encoder display blinks quickly.
o Then press the button to scroll through the menus (they scroll in a loop).
o When the "d" menu appears on the encoder, wait 3 seconds, until the settings encoder
display shows "u".
o Insert the USB stick into the USB port.
o The I-SAFE writes the data file on the USB stick and the dot next to the "u" flashes.
o Do not remove the USB stick while the dot flashes.
o When the display shows "d" again, the USB stick can be unplugged.
o Press the button again for 3 seconds and release when the display stops flashing.
o Scroll through the menus again until the encoder displays the code of the desired display
type (-, =, ≡, 1, 2, 3 or 4) .

Table of Contents