Electromagnetic Lock ( Located at outer end of barrier 24 VDC)
Electromagnetic Armature (Located stationary at outer end of barrier or at outer end of an opposite barrier)
TILT-A-WAY HYJG 1
ELECTROMAGNETIC LOCK
PEO277
PEO277
PEO246
PART NO.
IDEAL MANUFACTURING INC.
REF NO.
1
3
2
1/2" Strain Relief Fitting (one at barrier lower pipe)
26
DESCRIPTION
HYJG-218
REQ NO
1
1
1
THE ELECTROMAGNETIC LOCK IS CONNECTED TO AUXILIARY OUTPUT RELAY # 3
THE AUXILIARY OUT PUT RELAY NEEDS TO BE SET TO UNLOCK PULSE
PRESS AND HOLD BUTTON SW2 ON THE INTERFACE BOARD UNTIL THE DISPLAY CHANGES
RELEASE THE SW2 BUTTON AND THE DISPLAY WILL SHOW
MAIN MENU
UP / DOWN - VIEW MENUS
SELECT - VIEW / EDIT
RESET - EXIT
PRESS AND RELEASE BUTTON SW4 UNTIL THE DISPLAY SHOWS
TIMING AND OPTIONS
PRESS AND RELEASE BUTTON SW1 TO ENTER THE MENU
PRESS AND RELEASE BUTTON SW4 UNTIL THE DISPLAY SHOWS
AUXILIARY I / O
PRESS AND RELEASE BUTTON SW1 TO ENTER THE SUBMENU
PRESS AND RELEASE BUTTON SW4 UNTIL THE DISPLAY SHOWS
AUXILIARY OUTPUT # 3 FUNCTION
PRESS AND RELEASE BUTTON SW1 TO ENTER THE SUBMENU
PRESS AND RELEASE BUTTON SW4 UNTIL THE DISPLAY SHOWS
UNLOCK PULSE
PRESS AND RELEASE BUTTON SW1 TO SAVE SELECTION
PRESS AND RELEASE SW2 SWITCH
PRESS AND RELEASE SW4 BUTTON UNTIL THE DISPLAY SHOWS
AUXILIARY OUTPUT #3 PULSE DURATION
PRESS AND RELEASE BUTTON SW1 TO ENTER THE SUBMENU
PRESS THE SW4 BUTTON TO CHANGE TO 5.00 SECONDS
PRESS AND RELEASE BUTTON SW2 UNTIL YOU HAVE EXITED ALL MENUS