Protecting workers on-site
SAFETY SWITCH
Interlock Switches with Solenoid
HS5L
2-Contact / 4-Contact

Other manuals for IDEC HS5L Series

Question and Answer IconNeed help?

Do you have a question about the IDEC HS5L Series and is the answer not in the manual?

IDEC HS5L Series Specifications

General IconGeneral
Protection RatingIP67
Rated Voltage250 VAC, 30 VDC
Operating Temperature-25°C to 70°C
StandardsUL
Housing MaterialPlastic or Metal (Die-cast aluminum)

Summary

2-Contact Interlock Advantages

Optimized Contact Configuration

Switches with fewer contacts than needed reduce complexity and waste.

Enhanced Product Value and Compliance

Introduce safe machines complying with international standards for competitive advantage.

HS5 L Switch Applications

Suitable Machine Applications

Ideal for machines that do not shut down immediately or maintain high temperatures.

HS5 L Design & Performance Features

Compact and Slim Design

13% smaller than conventional models, reducing installation space and increasing flexibility.

Powerful 1400 N Locking Strength

Achieves high locking strength comparable to conventional models.

Rear Unlocking Button Functionality

Allows unlocking from inside hazardous areas, complying with ISO14119.

HS5 L Functional Enhancements

Spring Clamp Terminals

Offer excellent vibration resistance, preventing wire loosening without extra tightening.

Energy Saving Solenoid

Solenoid energy consumption reduced by 25% from conventional models.

Head Removal Detection Circuitry

Detects head removal to ensure switch integrity and safety.

HS5 Series Actuator Overview

Wide Variety of Actuators

Actuators selected based on door shapes, usage, and installation site for flexibility.

Spring Loaded Actuator

Patented actuator locks doors safely, tolerating up to 16mm bounce space.

HS5 L 2-Contact Specs & Features

Spring Lock Mechanism

Automatically locks actuator without power; manual unlocking available.

Solenoid Lock Mechanism

Locks when energized, unlocks when de-energized; flexible locking function.

Technical Specifications Overview

Covers applicable standards, ratings, operating conditions, and mechanical durability.

Marking for Locking Monitoring

Details marking requirements for lock monitoring according to ISO14119.

HS5 L 2-Contact Circuit Configurations

Circuit Codes and Contact Configuration

Defines circuit codes (XD, XF, XG, XH) and their contact arrangements.

Spring Lock Operating Characteristics

Illustrates operational states (Status 1-4) for spring lock models with circuit examples.

HS5 L 2-Contact Solenoid Lock Diagrams

Solenoid Lock Operating Characteristics

Shows operational states (Status 1-4) for solenoid lock models with circuit examples.

Operation Characteristics Reference

Provides reference for actuator entry and contact status based on position.

HS5 L 4-Contact Specs & Features

Spring Lock Operation Details

Explains automatic locking and manual unlocking for spring lock models.

Solenoid Lock Operation Details

Describes locking/unlocking based on solenoid power for solenoid lock models.

Technical Specifications for 4-Contact

Lists applicable standards, ratings, and durability for 4-contact models.

HS5 L 4-Contact Circuit Configurations

4-Contact Spring Lock Circuits

Details circuit codes (VA, VB, VC, VD, VF, VG) and their contact arrangements.

HS5 L 4-Contact Spring Lock Variants

4-Contact Rear Unlocking Button (Spring Lock)

Shows circuit configurations for models with rear unlocking button functionality.

4-Contact Dual Safety Circuit (Spring Lock)

Details circuit configurations for dual safety circuit models.

Dual SafetyRear Unlocking Button (Spring Lock)

Combines dual safety circuit and rear unlocking button features.

HS5 L 4-Contact Spring Lock Diagrams

4-Contact Rear Unlocking Button Diagrams

Illustrates operation states and circuit diagrams for rear unlocking button models.

Operation Characteristics Reference

Shows actuator entry position and contact status for various 4-contact spring lock circuits.

HS5 L 4-Contact Solenoid Lock Diagrams

4-Contact Solenoid Lock Circuits

Details circuit codes (VA7Y to VG7Y) and their contact arrangements for solenoid lock.

Solenoid Lock Operation States

Illustrates operational states for solenoid lock models with circuit examples.

HS5 L 4-Contact Dual Safety Diagrams

4-Contact Dual Safety Circuit Diagrams

Shows circuit diagrams and operation states for dual safety circuit models.

Dual SafetyRear Unlocking Button Diagrams

Illustrates circuit diagrams for models combining dual safety and rear unlocking.

HS5 Series Actuator Overview

Actuator Part Numbers and Descriptions

Lists available actuators (Straight, Right-angle, etc.) with part numbers and retention forces.

Actuator Accessories

Details accessories like sliding actuators, spring loaded actuators, and jumpers.

Actuator Dimensions and Mounting

Provides dimensional drawings and mounting hole layouts for straight and right-angle actuators.

Actuator Mounting & Orientation

Angle Adjustable Actuator Dimensions

Shows dimensions and mounting for angle adjustable vertical/horizontal actuators.

Actuator Orientation Adjustment

Explains how to change actuator swing orientation using the orienting insert.

Spring Loaded Actuator Mounting

Provides dimensions and mounting hole layouts for the spring loaded actuator.

HS5 L Switch Mounting & Rear Unlocking

Interlock Switch Dimensions and Mounting

Shows dimensions and mounting hole layouts for HS5L switches with indicator.

Rear Unlocking Button Kit Selection

Details part numbers and panel thickness compatibility for rear unlocking button kits.

HS5 L Safety & Installation

General Safety Precautions

Covers electrical safety, risk assessment, PLC usage, and solenoid lock considerations.

Installation Instructions

Provides guidance on door stops, shock prevention, actuator slot plugging, and storage.

Mounting Examples

Illustrates recommended mounting of interlock switch and actuator on doors.

Actuator Installation Guidelines

Hinged Door Radius Requirements

Specifies minimum door radius for different actuators on hinged doors.

Actuator Angle Adjustment

Details how to adjust actuator angle for proper insertion and locking.

HS5 LHS5 D Metallic Head Compatibility

Differentiates HS5L metallic heads from HS5D plastic heads for correct usage.

HS5 L Actuator & Switch Adjustments

Rotating the Head

Instructions for rotating the interlock switch head for different orientations.

Head Removal Detection Function

Explains function availability and limitations for spring lock models.

Spring Loaded Actuator Usage

Guidelines for using HS9Z-BA5 actuator, avoiding misuse as door lock/stop.

Actuator Adjustment Procedure

Step-by-step guide for adjusting actuator position for optimal locking.

Manual & Rear Unlocking Procedures

Manual Unlocking (Spring Lock)

Explains manual unlocking for spring lock switches for pre-checking and emergency use.

Manual Unlocking (Solenoid Lock)

Describes manual unlocking for solenoid lock switches in emergency cases.

Installing the Rear Unlocking Button

Instructions for installing the rear unlocking button and kit for manual override.

HS5 L Wiring & Installation Details

Recommended Tightening Torques

Lists recommended torque values for various switch and actuator components.

Wiring Examples and Cautions

Provides wiring diagrams and important considerations for connecting wires and using ferrules.

Applicable Cable Glands

Details cable gland compatibility for IP67 protection and different cable types.

HS5 L Wiring Connection Methods

Wire Connection Method

Step-by-step guide for connecting wires using the spring clamp terminal.

Connector Wiring Procedure

Instructions for wiring connectors, including cover removal and tightening order.

Installing the HS9 Z-JP5 L Jumper

Guide for installing a jumper to connect monitor circuits for safety input.