32 IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17
IDS1600 USER MANUAL
7. Press [#] to exit the Zone Menu.
M A I N M E N U
MRA ELBUORT
8. Press [#] to exit the Main Menu.
0 1 / 0 1 / 9 9 0 : 0 4
R E A D Y MO N
MRA ELBUORT
13. Buzz Zones
Buzz zones are used when Stay arming. When triggered, buzz zones
will cause the keypad buzzer to sound for a period of 30 seconds
during which time a valid user code must be entered. If a valid user
code is not entered during this period the system will register an
alarm condition. It is advisable to program Buzz zones if you are likely
to accidentally trigger these zones or if you have pets.
This feature helps prevent unnecessary false alarms
13.1To Program Buzz Zones
[4] + [ZONE NUMBER] + [] + [#]
1. Ensure the READY indicator is illuminated.
2. Hold down the [4] key until the keypad buzzer sounds.
3. Press the [NUMBER] corresponding to the zone you wish to be a
Buzz zone followed by the [] key.
4. The relevant Buzz zone will be shown by the illuminated zone
indicator. (Stay zones will be shown by flashing indicators. See
Section 12. A Stay zone cannot be selected as a Buzz zone;
the Stay status must be cleared first).
5. Repeat steps 1-3 until all the required Buzz zones are
programmed.
6. Press the [#] key to exit the buzz programming mode.