36 IDS1600 USER MANUAL NO. 700-146-01D ISSUED NOV 2002 VER 2.17
IDS1600 USER MANUAL
14. Chime Zones
The chime mode allows the user to monitor nominated zones while the
system is disarmed. The keypad buzzer will sound briefly when the
nominated zone is violated - the siren will NOT sound and no alarm
condition will be reported.
EXAMPLE:
You wish to know when someone enters or exits the front door, the
keypad will beep each time the door is opened if that zone is
programmed as a chime zone.
14.1 To Program the Chime Zones
[2] + [ZONE NUMBER] + [] + [#]
1. Hold down the [2] key until the keypad buzzer sounds.
2. The AWAY indicator will flash to show that the panel is In the
chime zone programming mode.
3. To program a zone as a chime zone, press the key corresponding
to that zone followed by the [] key.
4. Program any other zones you wish to select as chime zones as
per step 3.
5. Press the [#] key to exit the chime programming mode.
14.1.1To Program the Chime Zones - LCD Keypad
1. Hold down the [2] key until the keypad buzzer sounds.
C H I M E MO D E
MRA ELBUORT
2. Press the [MODE/ menu >] key.
Z O N E 1
F O R C H I ME Z O N E
MRA ELBUORT