ifm Device Manual IO-Link Master with Modbus interface CabinetLine 8 Ports IP 20 (AL1940) 05 / 2018
Configuration IoT Core
8.2.1 Configure IoT interface
16540
The parameters of the IoT port X23 are saved in the iotsetup substructure. The user can access the
following data points:
Access rights to the IO-Link master
0 = Modbus + IoT
1 = Modbus + IoT (read only)
2 = IoT only
IP address of the LR SMARTOBSERVER
Port number of the LR SMARTOBSERVER
Cycle time for data transmission to LR SMARTOBERVER (value in
milliseconds)
Configuration of the IP settings of the IoT port
0 = STATIC_IP/OFF
1 = DHCP/ON
iotsetup/network/ipaddress
IP address of the IoT port
iotsetup/network/subnetmask
Subnet mask of the network segment
iotsetup/network/ipdefaultgateway
IP address of the network gateway
rw ... read and write
Data point [iotsetup/accessrights]:
Different parameter settings in the Modbus projection software and the IoT applications can
result in undesired system behaviour. The values set in the Modbus projection software apply.