iDrive2 inverters Function Parameters
34
Detailed instruction of parameters
Motor V/F
slip
compensatio
n gain
This function code is used to compensate the change of
the rotation speed caused by load during running and
improve the stability of the motor. It can be set to the
rated slip frequency of the motor which is calculated as
below:
△f=f
b
-n*p/60
Of which, f
b
is the rated frequency of the motor, its
function code is P02.01; n is the rated rotating speed of
the motor and its function code is P02.02; p is the pole
pair of the motor. 100.0% corresponds to the rated slip
frequency△f.
Note: no torque compensation for single-phase 220V
inverters
Setting range:0.0~200.0%
Low
frequency
vibration
control factor
In the V/F control mode, current fluctuation may occur to
the motor on some frequency, especially larger kW
motors.. The motor runs unstable or overcurrent may
occur. This can be overcome by adjusting this
parameter.
The setting range of P04.10: 0~100
The setting range of P04.11: 0~100
The setting range of P04.12:0.00Hz~P00.03(the Max.
frequency)
High
frequency
vibration
control factor
Vibration
control
threshold
1: Automatic energy-saving
The motor adjusts the output voltage in non-load state
automatically.
P05 Group Input terminals
S1 terminals
function
selection
1: Forward rotation operation
2: Reverse rotation operation
3: 3-wire control operation
4: Forward rotation jogging
5: Reverse rotation jogging
S2 terminals
function
selection