IMO GmbH Gässlesweg 6 D-75334 Straubenhardt Tel.: 070 82 491 80 Fax: 604 36 www.imo-ag.com info@imo-ag.com
16
GmbH
4.5.4.2 Assign detergents to dosing pump
4.5.4.3 Suck detergents
4.5.4.4 Alter pumpfactor
4.5.5 Alter Code
Select / and press to choose the required dosing pump.
Afterwards press / , leaf the register of the available
detergents and choose with
Indication: The same detergent can’t be assigned to both
dosing pumps.
Select / to choose the required dosing pump and affirm .
The appropiate dosing pump is pumping as long as the -key
is pressed.
This function is need to flow the dosing tubes f.e. after replacement
of a used up detergent box.
Input of pump-capacity per dosing pump.
To aquire the quantity, pump up the water one minute by
suction-function and measure quantity of water.
The pump capacity should be checked once a year and
by supply corrected.
Indication: Not the capacity of dosing pump will be altered,
the capacity of dosing pump will be advertised to the control
of the equipment.
Used dosing hoses may be replaced.
Please find more information on chapter 5.6.7
By using a code-number you can make an access restriction of
the equipment. Code-no. 0000 this function is switched off.
The following fuction will be protected with the code-number:
programme new/alter
programme delete
changing of code
a
a
a
a
assign detergents
DOS1: no.: 2
component B2
DOS2: no.: 1
component A
asorb detergents
Dosage 1
Dosage 2
pump correction
DOS1: 150ml/min
DOS2: 150ml/min
alter code
code number: 0000