IMO GmbH Gässlesweg 6 D-75334 Straubenhardt Tel.: 070 82 491 80 Fax: 604 36 www.imo-ag.com info@imo-ag.com
19
GmbH
5.2 Step of rinsing
Water is filled:
The filled-in quantity of water is shown.
Water is heated.
The actually temperatur of water and the target
temperature is shown.
Water is be circulated, rinsing time runs.
The exhaused time and the target duration are indicated.
Conductivity of water is measured:
If there is no limit quoted, this part is dropped.
If the value of measure is smaller than the desired adjusted value,
all following rinsing-steps been void. If the value of measure is
higher than the desired adjusted value, the next rinsing step goes
on.
If there is no further rinsing step programmd, an error message
is issued. The rinsing program must be repeated, because an
inadequate result is to apprehend.
End of rinsing step, water is drained / pumped out.
programme no. 2
temp: 23°C / 40° C
duration: --min./ 10min.
Ec-value: --µS / 30µS
water: 0,7 litre
temp.: 20°C / 40° C
duration: ---min./ 10 min.
Ec-value: ---µS / 30µS
rinsing
programme no. 2
temp.: 40°C / 40°C
duration: 8 min./ 10 min.
Ec-value: --µS / 30µS
rinsing
programme no. 2
rinsing
temp.: --°C / 40°C
duration: --min./ 10 min.
Ec-value: 13µs / 30µS
programme no. 2
rinsing
temp.: --°C / 40°C
duration: --min./ 10min.
Ec-value: --µS / 30µS
programme no. 2
rinsing