Setting Tolerances - cont.
12
The next display will be “PLUS 1/ 0000.” The number entered here (0-9999) will allow a
Special Exception for 1 machine cycle per each group of x cycles the machine runs without feed.
Example: If the number programmed here is 100, nd the machine runs 600 cycles without feed,
the forces will be allowed outside normal limits during the first 6 machine cycles during which
the feed is again detected.
Enter the proper number and press the Enter/Yes key. The next display will show “ALL
FACTORS SET.”