• Unit in %: The value is the percentage of injected
volume of material before actuating the valve gate.
• Unit in mm: The value to enter is the stroke of
the injection screw before actuating the valve gate
(and not the position of the injection screw).
• Unit in cm3: The value to enter is the injected
volume of material before actuating the valve gate.
OPERATION
2
Important Notice: Select NONE with the left and
right arrows to erase a signal. This action will
automatcally erase the selected step and the
following if relevant.
Please note that the sequence programmed for
a channel is carried out until the injection signal
drops. Therefore, it is recommended to erase all
lines that are not required.