44
Safety Precautions and Technical Details
DAA007EN - 11.05.2021
TECHNICAL DETAILS
9 Technical details
9.1 Approved ambient conditions
The following ambient conditions apply:
electromagnetic conditions according to IEC61000-6-2 and DINEN55011 (limit
class A)
relative humidity (at 40 °C) max. 50%
max. altitude 1,000 m a.s.l.
ambient temperature at the location of use 10 °C to 40°C
ambient temperature during transport and storage -1C to 55°C (for 24 h also up
to 70°C)
If a fire extinguishing system is used: ambient temperature for transport and
storage of the machine is reduced to -10 °C to +50 °C.
brightness conditions at the machine according to DINEN12464
contamination of environment within the scope of the contamination caused by
the machine itself
no ionizing or non-ionizing radiation
no explosion hazard in the environment
strong and vibration-free foundation
conductive grounding transitions less than1megaohm for optimum operation of
the capacitive touch panel
In the case of all optional components, the details in the purchased-part documenta-
tion for the components must be observed.