Getting Started
1. Install the batteries and sensor as described below.
2. Slide the OFF-LOW-HIGH Sensitivity switch to the HIGH
position.
3. Wait for the TEK-Mate to warm up. A high-pitched audible tone
will be heard and the LEAK indicator will be illuminated while
the TEK-Mate is warming up. When this tone changes to a chirp
and the LEAK indicator starts ashing, the TEK-Mate is ready
to nd leaks.
4. Begin checking for leaks.
The INFICON TEK-Mate Refrigerant Leak Detector provides similar
responses to all CFC's, HCFC's, HFC's and refrigerant blends (i.e.
R-404A, R407c) as well as SF6. There is no need to select the
refrigerant you're working with.
How to Install the Alkaline Batteries
1. Remove the battery cover by releasing the latch and sliding the
cover down and off the handle.
2. Install two D size alkaline batteries as shown in Figure 1.
3. Reinstall the battery cover by aligning it with the handle and
sliding it up until the latch engages.
When the batteries are nearing the end of their useful life, the yellow
Low Battery indicator illuminates. While the batteries may operate
the TEK-Mate up to a period of one hour after the Low Battery
indicator illuminates, the batteries should be replaced as quickly as
possible.

Other manuals for Inficon TEK-Mate

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inficon TEK-Mate and is the answer not in the manual?

Inficon TEK-Mate Specifications

General IconGeneral
BrandInficon
ModelTEK-Mate
CategorySecurity Sensors
LanguageEnglish

Related product manuals