TECHNICAL HANDBOOK
kina22e1-p (1206) Translation of the original instruction
Catalog No.
530-001
530-002
530-103
530-104
530-105
530-106
from software version V 2.4
Ecotec E3000
Multi-Gas Leak Detector

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Inficon Ecotec E3000 530-001 and is the answer not in the manual?

Inficon Ecotec E3000 530-001 Specifications

General IconGeneral
ModelEcotec E3000
Part Number530-001
TypeRefrigerant Leak Detector
Response time<1 second
Operating temperature0°C to 45°C (32°F to 113°F)
Power supplyRechargeable battery or AC adapter
Resolution1 ppm
RefrigerantHFC, HCFC, CFC, HFO, and natural refrigerants
OutputRS-232

Summary

General Information

1.1.1 Intended Use

Details the applications and proper usage guidelines for the Ecotec E3000 as a refrigerant leak detector.

1.3.2 Technical Data

Provides detailed physical, electrical, and other technical specifications for the Ecotec E3000 leak detector.

1.6 Installation

Details initial setup and connection procedures required before operating the Ecotec E3000.

How the Instrument Works

2.1 Description of the Functions

Explains the core functionality of the Ecotec E3000 using its mass spectrometer.

2.2 Description of the Subassemblies

Details the main components of the Ecotec E3000, including pumps and spectrometer.

Operation of the Ecotec E3000

3.1 Start-Up

Guides on the initial startup procedure, including connecting cables and self-test.

3.2 Controls on the main display unit

Details the operation of the main display unit's keys for menu navigation and measurement display.

3.3 Controls on the probe display unit

Explains the controls and display functions on the sniffer probe handle for remote operation.

3.4 Performing measurements

Outlines the Standard Operation and IullGuide Operating Modes for leak detection.

3.4.1 Standard Operation Mode

Step-by-step guide for performing measurements in standard mode.

3.4.2 IullGuide Operating Mode

Explains the IullGuide mode for guided leak detection, including setup and program selection.

3.5 Calibration and Self-Test

Covers procedures for internal and external calibration, including self-tests.

3.5.1 Verifying a calibration (proof function)

Details how to perform a verification or proof function using the ECO-Check reference leak.

3.5.2 Internal calibration

Explains the process of performing internal calibration using the ECO-Check reference leak.

3.5.3 External calibration

Guides on conducting external calibration using an external calibrated leak.

Equipment Settings

4.4 Selecting gases and setting gas triggers

Covers selecting gases and configuring trigger values and measurement units.

4.4.1 Editing gas parameters

Details on modifying gas-specific settings like mode, trigger, limits, and calibration factors.

4.4.7 Activating the Interfering Gas Suppression (IGS)

How to activate the IGS mode to suppress false alarms caused by specific gas mixtures.

4.5.1 Vacuum & Access Menu

Settings for ZERO function, flow limits, and sensitivity check monitoring.

4.5.4 Setting-up / editing an IullGuide Program

Creating and modifying IullGuide programs, including cycle counters and button functions.

4.6 Interfaces

Configuration of control location, recorder outputs, RS232 protocol, and PLC connections.

4.8 History & Maintenance

Viewing historical data such as error lists, calibration history, and maintenance records.

Ecotec E3000 Messages

5.1 Error Messages and Warnings

Explains how the Ecotec E3000 displays and handles errors and warnings via self-diagnostic functions.

Detecting Specific Gases

Maintenance

8.1 Maintenance schedule

Provides a schedule for required maintenance tasks, including intervals and part numbers.

Related product manuals