Operating Manual
D-TEK Stratus
®
Refrigerant Leak Detector and Portable Monitor
English · Español · Deutsch · Français · Italiano · 中文 ·日本語 · Pyccĸий·
Polski · Svenska · Türkçe · Nederlands · 한국어
074-708-P16A

Table of Contents

Other manuals for Inficon D-TEK Stratus

Questions and Answers

  • K
    Katherine StephensAug 13, 2025
    What to do if my Inficon D-TEK Stratus Security Sensors unit turns on but doesn't detect refrigerant?
    • C
      Christopher JohnsonAug 14, 2025
      There could be several reasons: 1. The unit may not have completed warm-up. Wait for 45 to 90 seconds until warm-up is complete. 2. The filter might be clogged, restricting airflow. Replace the filter cartridge. 3. The pump may have failed. Listen for the pump sound. If there's no sound and the battery is charged, contact INFICON.
  • J
    Joel Cook DDSAug 17, 2025
    Why is my Inficon D-TEK Stratus Security Sensors unit alarming in clean air?
    • B
      Bobby DunnAug 18, 2025
      This could be due to: 1. A covered exhaust port. Make sure the exhaust port is not covered. 2. An incorrectly installed sensor. Verify that the refrigerant sensor is installed, not the CO sensor.
  • M
    Matthew FloresAug 21, 2025
    What to do if the display of my Inficon D-TEK Stratus Security Sensors does not turn on after pressing the power button?
    • L
      Laura RileyAug 21, 2025
      If the display doesn't turn on, the battery level may be critically low. Charge the battery or plug the unit into a charger.
  • C
    Christine MillerAug 25, 2025
    What does it mean if my Inficon Security Sensors displays a battery symbol?
    • R
      Renee BeckAug 26, 2025
      A battery error has occurred. This can be caused by a failed battery, improper battery installation, or a poor connection. Remove and reinstall the battery. If the problem persists, replace the battery.
  • R
    Renee RyanAug 28, 2025
    What does it mean if my Inficon Security Sensors displays a sensor symbol?
    • D
      Dorothy PetersonAug 28, 2025
      A sensor error has occurred. This can be caused by a failed sensor, or by the sensor being improperly installed, or having a poor connection. Remove and reinstall the sensor. If the problem is not fixed, replace the sensor.
  • H
    Holly WattsSep 1, 2025
    Why does the ppm fall to zero in a contaminated area with my Inficon D-TEK Stratus?
    • D
      dylanyoungSep 1, 2025
      The reference sample may be contaminated. Let D-TEK Stratus run in clean air in Cloud Hunting mode for up to five minutes.
  • L
    Laurie HowardSep 5, 2025
    What does it mean if my Inficon Security Sensors displays a battery temperature symbol?
    • M
      mathewjohnstonSep 5, 2025
      The battery is above or below the ideal temperature range and may not charge properly. Allow the battery to return to normal temperature.
  • B
    brianstewartSep 9, 2025
    How to fix the pump if it is not making a sound in Inficon D-TEK Stratus?
    • J
      johnsonpamelaSep 9, 2025
      If the battery has a proper charge, contact INFICON.

Summary

Cautions and Warnings

Refrigerant Concentration Hazard

Warns about dangers of high CO2 or refrigerant concentrations.

Specifications

Charging the Battery

Instrument Operation and Preparation

Cloud Hunting Mode

Pinpoint Mode

Using Pinpoint Mode

Guide to using Pinpoint mode for detecting leaks with auto-zeroing.

Manual Zero Mode

Using Manual Zero Mode

Explains how to use Manual Zero mode, including manual zeroing and beep rate indication.

Battery Removal and Installation

Battery Removal Procedure

Step-by-step guide on how to remove the battery door and eject the battery.

Battery Installation Procedure

Instructions for aligning and inserting the battery and reinstalling the battery door.

Sensor Removal and Installation

Sensor Replacement Steps

Procedure for removing the old sensor and installing a new one, including alignment.

Replacing Filters

Filter Replacement Guide

Instructions on how to replace the filter cartridge, including screw-on probe tip.

Carbon Dioxide Sensor

Using the CO2 Sensor

Information on installing and using the optional CO2 sensor for leak detection.

CO2 Exposure Safety Warning

Safety warning regarding high concentrations of CO2 and refrigerants, and respirator use.

Troubleshooting Guide