1.3. Specifications
Detector
Resolution
256
×
192
Pixel Size
12
μm
NETD
≤50mK@25
, F#1.0
Spectral Band
8
14
μm
Performance
Frame Rate
25Hz
Operating
Temperature
-10
℃~
55
Storage
Temperature
-40
℃~
85
Power
Consumption
350mw
Processor
Self-developed LY ASIC chip
Lens
Focus Length
3.2mm
Aperture
F1.1
FOV
56.0° (H)×42.2° (V), 71.3°(D)
Focusing Mode
Athermalized Prime Lens
Temperature
Measurement
Object
Temperature
Range
-10
~550
Measuring
Accuracy
±2
or ±2% of readings, whichever is greater
Temperature
Correction
Distance, ambient temperature, and emissivity
Shell
Size (w
×
h
×
d)
27
×
18
×
9.8(mm)
Color
Silver
Weight
About 9.5g
Product Interface
USB type C
Note: The parameters are updated on June 15, 2022, and are subject to change without notice.
Note: The above temperature measurement parameters are obtained in the laboratory environment.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the InfiRay P2 Pro and is the answer not in the manual?

InfiRay P2 Pro Specifications

General IconGeneral
Resolution256x192
Frame Rate25 Hz
Pixel Size12μm
Accuracy±2°C or ±2%
Focus ModeFixed
InterfaceUSB Type-C
FocusFixed
NETD<40mK
Temperature Range-20°C to 550°C
Spectral Range8-14μm
DisplayVia connected device
Battery LifeN/A (USB powered)
Operating Temperature-10°C to 50°C