8
3.2.3 Temperature Setting
(1) Temperature Unit
The temperature unit can be selected as Celsius (), Fahrenheit (), or Kelvin (K).
(2) Temperature Alarm
In the alarm setting, users can set the threshold.
High temperature alarm: enter a threshold and save. The phone sounds an alarm when any temperature shown on the
image exceeds the threshold.
Low temperature alarm: enter a threshold and save. The phone sounds an alarm when any temperature shown on the
image is lower than the threshold.
(3) Burn Protection
When it is detected that the infrared image temperature measurement exceeds the specified time of threshold
temperature, the shutter plate will be closed, and a window will be popped up to prompt that the burn protection is enabled.
Please do not aim at high-temperature objects for a long time. If you need to release it, please press the shutter plate!
3.2.4 General
Users can set the language in the General interface.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the InfiRay P2 Pro and is the answer not in the manual?

InfiRay P2 Pro Specifications

General IconGeneral
Resolution256x192
Frame Rate25 Hz
Pixel Size12μm
Accuracy±2°C or ±2%
Focus ModeFixed
InterfaceUSB Type-C
FocusFixed
NETD<40mK
Temperature Range-20°C to 550°C
Spectral Range8-14μm
DisplayVia connected device
Battery LifeN/A (USB powered)
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C