35/57 Telium Troubleshooting Guide / June 28, 2014
7_1_2 iPP320 and iPP350 Power Requirements
An external power supply is required when connecting the iPP320 or iPP350 to the Host via Ethernet and 5m length RS-232 cables.
Ingenico specifies a DC power supply (model number 179901469) for this device. These terminals may also be powered from a POS
via the USB (5V, 500mA) interface.
Connect the cable to the Multipoint port before connecting power to the terminal. Only use the power supply which was
provided by Ingenico.
Do not disconnect power from the terminal until you have been instructed to do so.
Before you disconnect the terminal from the POS, you must first disconnect power in order to prevent damage to the
terminal.
7_1_3 iPP320 and iPP350 Secure Access Modules
There are three Secure Access Module (SAM) slots designed to hold full-size SAM cards. These slots are accessible via an access
door on the bottom of the device as shown in the below image.