6 General information
Fire alarm and extinguishing system
Note: The notes contain important information relating to the text.
Attention: The “Attention” prompts indicate that total or partial disregard of the procedure could damage the
device or its peripherals.
EN54: Such indications indicate that the information and instructions refer to European standards.
Cables: Such indications state the types and specifications of the
cables which must be used for the wiring in accordance
with the manufacturer's advice or the standard concerned.
1.4 Operator classification - Access Levels
The control panel has 4 distinct access levels:
Level 1: Public level - this is the normal access level of the control panel and is the access level for building inhabitants
who are neither authorized to use the system nor instructed in its use.
At this level it is possible to view the information on the display and on the signalling LEDs, as well as to interact using the
buttons and the touch screen to scroll through the information. Level 1 allows the following operations only:
mute buzzer
test signalling LEDs
activate alarm signalling when an early-warning process is running
Level 2: Authorized users - this access level is for the system supervisors and is for authorized personnel who are
adequately instructed in the use of the system and its functions.
Access requires the use of a key or entry of a valid access code with sufficient access rights. In addition to the operations
described for level 1 it is also possible to carry out the following operations:
mute alarm signalling devices
rearm the control panel
activate alarm signalling devices manually
disable control panel elements
place in test status one or more of the system elements
bypass and activate objects which require this specific level.
The system provides two additional sub-levels of authorized user:
- Superuser level, las for the previous one, with the added possibility of registering control panels to their account
with the Inim Cloud service
- Maintenance operator level, same as the previous level with the added possibility of stopping the valve pulse for
those models that support extinction functions
Level 3: Programming - this access level is for specialized technical operators who carry out system configuration,
commissioning and maintenance.
Access requires entry of a valid access code with sufficient access rights after inserting a jumper which enables
programming. Refer to the manual for system configuration, commissioning and maintenance.
ONLY authorized technicians, appointed by the Manufacturer can, by means of special tools, carry out repair work on
the motherboard.
Level 4: only authorized technicians, appointed by the Manufacturer can, by means of special tools, carry out repair
work on the motherboard.
1.5 CE Mark
1.5.1 Regulation (EU) No. 305/2011
This product complies with requirements stated by standards listed here below in compliance with Regulation (EU) No.
305/2011.