Inner Range Inception Security Controller Installation Manual. Rev. 6.0
© 2016 - 2023. Inner Range Pty Ltd.
22 www.innerrange.com
Specifications
Case Material:
ABS plastic.
Dimensions:
205mm / 8.1” x 94mm / 3.7” x 38mm / 1.5”
Shipping Weight (gross):
1.2kg / 2.65lbs
Installation environment:
0º to 49º C / 32º to 120º F.
@ 15%-85% relative humidity (non-condensing)
Power Source.
-To “DC IN” (Recommended):
-To “BATT” (Alternate method):
“DC IN” not connected.
18V to 24V DC. 2.5A. e.g. The supplied 24V 2.5A PSU.
Note: 12V, SLA Battery of 7AH to 18AH capacity must be
connected to ‘BATT’ input.
12.8V-14V DC. 2.8A.
i.e. A separate external battery-backed power supply is used.
Battery:
12 Volt Sealed Lead-Acid (gel) type. 7 to 18 Amp-Hour.
Idle current consumption.
-DC IN = 24V DC:
-BATT (DC IN= 0V):
Note: Does not include Battery charging or current required by any
peripheral devices.
60mA (85mA with Ethernet connected)
110mA (150mA with Ethernet connected)
Additional current required for:
-Built-in Relays (OUT1 OUT4)
-Inception Wireless Adapter:
-4-Port USB Hub with 12VDC input:
25mA per relay. (33mA when Controller powered from ‘BATT’ i/p)
25mA (40mA when Controller powered from ‘BATT’ i/p)
See manufacturer’s datasheet. Must be powered via 12VDC input,
not the Inception USB port. Allow for current required by any
device connected to a USB Port.
Power supply outputs.
See Separate Table On The Following Page.
Battery Charger output voltage:
13.75V DC.
Battery charger output current:
Up to 500mA.
Typical Battery Backup Time.
7AH Battery:
18AH Battery:
18AH Battery:
Controller connected to Ethernet or Wi-Fi + 1 LCD Terminal + up
to 200mA for other devices (PIRs, communicator, reader, etc.).
16 Hours.
40 Hours.
Configuration as above but up to 500mA for other devices.
24 Hours.
Typical Battery Recharge Time.
7AH Battery:
18AH Battery:
To full charge after providing backup at the loads specified &
periods listed above.
18 Hours
42 Hours
AC Fail detect (On “DC IN”):
16.5V DC
Low battery detect (On “BATT” I/P):
11.0V DC
Output Fuses:
Individual PTC protection, self-resetting.
Battery Input Fuse:
7A. Non-replaceable. If blown, unit must be returned for repair.
Battery deep discharge protection.
Activated: 10.4V Restored: 12.5V
Battery replacement period:
5 years max. 3 years typical. Refer to battery manufacturers
recommendations & relevant local standards.
Zone inputs:
8
Relay outputs:
4 (‘OUT1-4’)
Relay contact rating:
5 Amps. 30v DC or AC. See Note 3 below.
USB version:
2.0
Alarm Reporting Formats:
Contact ID. IR-fast. (via T4000 or SkyTunnel)