Inner Range Inception Security Controller Installation Manual. Rev. 6.0
© 2016 - 2023. Inner Range Pty Ltd.
4 www.innerrange.com
REGULATORY INFORMATION
UL294 Requirements (North America)
• Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities
having jurisdiction.
• The Inception Controller, remote Modules and UniBus in-cabinet expansion boards are acceptable for indoor use only and
must be installed within the protected premises.
• The AC power cord must not be plugged into an outlet controlled by a switch.
• If a separate power supply is utilized for ancillary power (e.g. For electric locks), the power supply must be a UL Listed
Access Control or Burglar Alarm, Low-Voltage Class 2, Power-Limited, power source capable of a minimum of 4 hours
standby power.
• All cabling must be UL Listed and/or Recognized wire.
• All interconnecting devices must be UL Listed.
• The Inception access control system must be used with UL listed Card Readers.
• The following Listed Card Readers configured for Wiegand or RS485 (OSDP) output are compatible:
- Inner Range SIFER Reader - HID iClass - HID Proximity
- Inner Range SIFER-Keypad - HID iClass SE
• Automation. The Automation functionality of this product has not been evaluated by UL.
• FUSES. CAUTION - FOR CONTINUED PROTECTION AGAINST THE RISK OF FIRE, REPLACE WITH ONLY THE SAME TYPE AND
RATING OF FUSE.
• Refer to the ‘Additional Resources’ chapter of this manual for a list of related documentation.
ULC-S304 Requirements (Canada)
• Inception Controller total static load current must not exceed 450mA. i.e. Combined current required by the Controller
and devices powered from the LAN+, READER+, V OUT & USB outputs.
UL2610 Requirements (North America)
INSTALLATION NOTES:
• Loss of communication with the monitoring station shall be treated as an alarm condition by monitoring station personnel
when the burglar alarm system is in the armed state, and as a trouble condition while the system is disarmed.
• Communication medium between protected property & communications service provider shall be for the exclusive use of
the protected property and is not to be shared with other communications service provider subscribers.
• The number of signals in each system used for burglar-alarm signals shall be limited to 1000.
• The central/proprietary/police (monitoring) station equipment shall be designed and constructed so that any critical
component can be replaced and the system restored to service within 30 minutes.
PROGRAMMING NOTES:
Message Acknowledge “Acknowledgement signal”.
The settings for User acknowledgement of alarm messages are programmed in Configuration > Users as follows:
• In Terminal Profiles > Terminal Permissions, enable the ‘System Messages/Warnings’ option.
• In Manage Users > Credentials, assign the appropriate ‘Terminal Profile‘ to each User who has a Security PIN.
Entry and Exit Delay: The Entry & Exit delay settings are programmed separately for each Area.
The value programmed for Entry or Exit delay must not exceed 60 seconds.