- 66 -
Function
code
Name LED display Setup range
Minimu
m unit
Factory
default
value
Modific-
ation
descrip-t
ion
F2-09
Torque upper
limit
Torque upper
limit
0: F2-10
1: AI1
2: AI2
3: AI3
4: Reserved
5: Communication
setup
Analog input scale
corresponds to
F2-10.
1 0
F2-10
Torque upper
limit
Torque upper
limit
0.0%250.0% 0.1% 200.0%
F2-11
Encoder pulse
number
Encoder pulse
number
165535 1 1024
F2-12 Reserved
F2-13
D axis current
loop Kp
D axis current
loop Kp
065535 1 50
F2-14
D axis current
loop Ki
D axis current
loop Ki
065535 1 50
F2-15
Q axis current
loop Kp
Q axis current
loop Kp
065535 1 50
F2-16
Q axis current
loop Ki
Q axis current
loop Ki
065535 1 50
F2-17
SoftPwm
selection
SoftPwm
selection
0: Inenabled
1: Enabled
1 0
Group F3 V/F Control Parameters
F3-00 V/F curve setup V/F curve setup
0: Straight V/F curve
1: Multiple-point V/F
curve
2: Square V/F curve
1 0