- 101 -
value.
Prompt: There is difference between the auxiliary frequency source Y
selection and the main frequency source X setup value. That is to say, the
main and auxiliary frequency sources cannot use the same frequency setup
channel.
Auxiliary Frequency
source Y relative value
selection
Factory default
value
0
0 Relative to maximum frequency
F0-05
Setup
Range
1 Relative to frequency source X
Auxiliary Frequency
source Y
Factory default
value
0
F0-06
Setup Range 0% to 100%
When the frequency source selection is frequency superimpositon setup
(F0-07 is set to 1 or 3), it is used to determine the adjustment range of
auxiliary frequency source. F0-05 is used to determine the relative object of
that range. If it is relative to maximum frequency X, that range will vary with
the main frequency X.
Frequency source
selection
Factory default
value
0
0 Main frequency source X
1
Main frequency source X plus
auxiliary frequency source Y
2
Switching between main frequency
source X and auxiliary frequency
source Y
3
Switching between main frequency
source X and (main frequency
source X plus auxiliary frequency
source Y)
F0-07
Setup
Range
4
Switching between main frequency
source Y and (main frequency
source X plus auxiliary frequency
source Y)
This parameter is used to select the frequency setup channel. Frequency
setup is realized through combination of main frequency source X and
auxiliary frequency source Y.