- 91 -
Select the
reverse of
feedback
speed
Factory
default value
0
0
Select the forward direction of speed
direction
A1-03
Setup
range
1
Select the reverse direction of speed
direction
Rotary
transformer
number of
pole-pairs
Factory
default value
1
A1-04
Setup
range
150
Group A2 CAN Communication Group
Baud rate
selection
Factory
default value
4
0 20k
1 50k
2 125k
3 250k
4 500k
A2-00
Setup
range
5 1M
CAN
communication
address
Factory
default value
1
A2-01
Setup
range
1255
A2-02
CAN
communication
continuous
time